Analysis and mitigation of high frequency harmonic interference in high voltage power line carrier coupling systems.
紀錄類型:
書目-電子資源 : 單行本
正題名/作者:
Analysis and mitigation of high frequency harmonic interference in high voltage power line carrier coupling systems./
作者:
Franklin, Gregory A.
面頁冊數:
164 p.
附註:
Source: Dissertation Abstracts International, Volume: 67-01, Section: B, page: 0430.
Contained By:
Dissertation Abstracts International67-01B.
標題:
Engineering, Electronics and Electrical. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3201154
ISBN:
9780542489143
Analysis and mitigation of high frequency harmonic interference in high voltage power line carrier coupling systems.
Franklin, Gregory A.
Analysis and mitigation of high frequency harmonic interference in high voltage power line carrier coupling systems.
- 164 p.
Source: Dissertation Abstracts International, Volume: 67-01, Section: B, page: 0430.
Thesis (Ph.D.)--The University of Alabama at Birmingham, 2005.
Interference resulting from high-frequency power system harmonics in the band below 10 kHz has been previously reported to adversely affect high-voltage power line carrier coupling systems. Problems such as equipment failures and carrier signal interference have been experienced. Previous work by others has characterized the nature and origin of power line carrier coupling system problems caused by harmonic frequency interference. However, computer-based modeling of coupling systems suitable for frequency response analysis was not made available. Also not made available by previous work was an analysis of simple and inexpensive methods for mitigating harmonic frequency interference. The results of the study presented expand previous work by providing an additional resource on high-frequency harmonic interference. Frequency response measurements of three common types of coupling systems using typical coupling capacitance and drain coil inductance values are provided. Also presented are state-space models of the coupling systems suitable for estimating the frequency responses of the coupling systems in the harmonic frequency band. Finally, coupling system components that can be altered for problem mitigation are identified, along with an example of interference mitigation on a 230-kV coupling system that was severely affected by harmonic frequency interference.
ISBN: 9780542489143Subjects--Topical Terms:
170927
Engineering, Electronics and Electrical.
Analysis and mitigation of high frequency harmonic interference in high voltage power line carrier coupling systems.
LDR
:02322nmm 2200265 4500
001
1000004776
005
20061114130301.5
008
061114s2005 eng d
020
$a
9780542489143
035
$a
(UnM)AAI3201154
035
$a
AAI3201154
040
$a
UnM
$c
UnM{me_controlnum}
100
1
$a
Franklin, Gregory A.
$3
1000005864
245
1 0
$a
Analysis and mitigation of high frequency harmonic interference in high voltage power line carrier coupling systems.
300
$a
164 p.
500
$a
Source: Dissertation Abstracts International, Volume: 67-01, Section: B, page: 0430.
500
$a
Adviser: Gregg L. Vaughn.
502
$a
Thesis (Ph.D.)--The University of Alabama at Birmingham, 2005.
520
$a
Interference resulting from high-frequency power system harmonics in the band below 10 kHz has been previously reported to adversely affect high-voltage power line carrier coupling systems. Problems such as equipment failures and carrier signal interference have been experienced. Previous work by others has characterized the nature and origin of power line carrier coupling system problems caused by harmonic frequency interference. However, computer-based modeling of coupling systems suitable for frequency response analysis was not made available. Also not made available by previous work was an analysis of simple and inexpensive methods for mitigating harmonic frequency interference. The results of the study presented expand previous work by providing an additional resource on high-frequency harmonic interference. Frequency response measurements of three common types of coupling systems using typical coupling capacitance and drain coil inductance values are provided. Also presented are state-space models of the coupling systems suitable for estimating the frequency responses of the coupling systems in the harmonic frequency band. Finally, coupling system components that can be altered for problem mitigation are identified, along with an example of interference mitigation on a 230-kV coupling system that was severely affected by harmonic frequency interference.
590
$a
School code: 0005.
650
4
$a
Engineering, Electronics and Electrical.
$3
170927
690
$a
0544
710
2 0
$a
The University of Alabama at Birmingham.
$3
1000005450
773
0
$t
Dissertation Abstracts International
$g
67-01B.
790
1 0
$a
Vaughn, Gregg L.,
$e
advisor
790
$a
0005
791
$a
Ph.D.
792
$a
2005
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3201154
$z
0 筆讀者評論
館藏地:
全部
線上資料庫
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約人數
備註欄
附件
OE0000751
線上資料庫
線上資源
線上電子書
OE
一般(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
建立或儲存個人書籤
書目轉出
取書館別
處理中
...
變更密碼
登入