Language:
繁體中文
English
日文
說明(常見問題)
南開科技大學
圖書館首頁
編目中圖書申請
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Internal combustion engine cooling s...
~
Chastain, John Howard, Jr.
Internal combustion engine cooling strategies: Theory and test .
紀錄類型:
書目-電子資源 : 單行本
正題名/作者:
Internal combustion engine cooling strategies: Theory and test ./
作者:
Chastain, John Howard, Jr.
面頁冊數:
175 p.
附註:
Source: Masters Abstracts International, Volume: 45-02, page: 1040.
Contained By:
Masters Abstracts International45-02.
標題:
Engineering, Automotive. -
電子資源:
Download PDF (下載PDF全文)
ISBN:
9780542963001
Internal combustion engine cooling strategies: Theory and test .
Chastain, John Howard, Jr.
Internal combustion engine cooling strategies: Theory and test .
- 175 p.
Source: Masters Abstracts International, Volume: 45-02, page: 1040.
Thesis (M.S.)--Clemson University, 2006.
Advanced automotive thermal management systems integrate electro-mechanical components for improved fluid flow and thermodynamic control action. Progressively, the design of ground vehicle heating and cooling management systems require analytical and empirical models to establish a basis for real time control algorithms. One of the key elements in this computer controlled system is the smart thermostat valve which replaces the traditional wax-based unit. The thermostat regulates the coolant flow through the radiator and/or engine bypass to control the heat exchange between the radiator's coolant fluid and the ambient air. The electric water pump improves upon this concept by prescribing the coolant flow rate based on the engine's overall operation and the driver commands rather than solely on the crankshaft speed. The traditional radiator fan is belt driven and equipped with a clutch to limit parasitic loads during operating conditions that provide sufficient radiator heat rejection. A DC motor-driven radiator fan offers improved control over the air flow rate to better regulate radiator heat rejection while reducing power consumption. Ideally, the thermal management system will accept multiple engine sensor feedback including, but not limited to, the engine cylinder temperature, oil temperature, coolant temperature, engine block temperature, engine load, and throttle angle. To achieve this concept, these electrically driven system components must be mathematically described, computer controlled, and configured on an internal combustion engine.
ISBN: 9780542963001Subjects--Topical Terms:
1000006179
Engineering, Automotive.
Internal combustion engine cooling strategies: Theory and test .
LDR
:04555nmm 2200301 4500
001
1000004999
005
20070601084756.5
008
070601s2006 eng d
020
$a
9780542963001
035
$a
(UnM)AAI1439215
035
$a
AAI1439215
040
$a
UnM
$c
UnM{me_controlnum}
100
1
$a
Chastain, John Howard, Jr.
$3
1000006178
245
1 0
$a
Internal combustion engine cooling strategies: Theory and test .
300
$a
175 p.
500
$a
Source: Masters Abstracts International, Volume: 45-02, page: 1040.
500
$a
Adviser: John Wagner.
502
$a
Thesis (M.S.)--Clemson University, 2006.
520
$a
Advanced automotive thermal management systems integrate electro-mechanical components for improved fluid flow and thermodynamic control action. Progressively, the design of ground vehicle heating and cooling management systems require analytical and empirical models to establish a basis for real time control algorithms. One of the key elements in this computer controlled system is the smart thermostat valve which replaces the traditional wax-based unit. The thermostat regulates the coolant flow through the radiator and/or engine bypass to control the heat exchange between the radiator's coolant fluid and the ambient air. The electric water pump improves upon this concept by prescribing the coolant flow rate based on the engine's overall operation and the driver commands rather than solely on the crankshaft speed. The traditional radiator fan is belt driven and equipped with a clutch to limit parasitic loads during operating conditions that provide sufficient radiator heat rejection. A DC motor-driven radiator fan offers improved control over the air flow rate to better regulate radiator heat rejection while reducing power consumption. Ideally, the thermal management system will accept multiple engine sensor feedback including, but not limited to, the engine cylinder temperature, oil temperature, coolant temperature, engine block temperature, engine load, and throttle angle. To achieve this concept, these electrically driven system components must be mathematically described, computer controlled, and configured on an internal combustion engine.
520
$a
A unique experimental platform has been developed featuring a 4.6L V8 engine, with extensive block-embedded thermocouples, attached to a water-brake dynamometer. Three physical cooling system configurations were tested for prescribed engine temperature tracking and power consumption: an electrically driven fan in combination with a wax-based thermostat and a crank shaft driven cooling pump (Tests 1 & 2); a servo-motor driven radiator fan and smart thermostat valve in combination with the engine driven cooling pump (Tests 3 & 4); and an electrically driven radiator fan, smart thermostat valve, and servo-motor coolant pump (Tests 5 & 6). These cooling system configurations facilitated the testing of three different controller concepts based on factory emulation, classical control, and thermodynamic optimization. Each cooling system is evaluated with a test profile encompassing steady state and transient engine operation by including step changes in the engine speed, engine load, and air speed. Data acquisition and control activities were supported by a dSPACE DS1104 hardware board which managed the real-time interface between the Control Desk software and the physical system.
520
$a
The experiments demonstrated that steady state coolant temperature regulation was improved with computer control of the radiator fan, thermostat valve, and coolant pump (Tests 5 & 6) which is noted by accurately tracking the set point temperature within +/-0.5°C. Most importantly this system (Test 5 & 6) was able to meet the cooling needs with 60W power consumption. A reduction of 478W parasitic energy use in situations where vehicle ram-air provided a sufficient heat rejection rate when compared to the factory emulation power use of 538W(Test 1). However, with this increased level of control, the system revealed temperature variations of +/-3.0°C in Test 3 versus +/-0.1°C in Test 1 during transient response to ram-air. Overall, computer control of the automotive cooling system enhances temperature tracking ability and reduces the parasitic loading.
590
$a
School code: 0050.
650
4
$a
Engineering, Automotive.
$3
1000006179
650
4
$a
Engineering, Mechanical.
$3
170925
690
$a
0540
690
$a
0548
710
2 0
$a
Clemson University.
$3
1000005649
773
0
$t
Masters Abstracts International
$g
45-02.
790
1 0
$a
Wagner, John,
$e
advisor
790
$a
0050
791
$a
M.S.
792
$a
2006
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1439215
$z
Download PDF (下載PDF全文)
0 筆讀者評論
館藏地:
全部
線上資料庫
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約人數
備註欄
附件
OE0000974
線上資料庫
線上資源
線上電子書
OE
一般(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
建立或儲存個人書籤
書目轉出
取書館別
處理中
...
變更密碼
登入