Language:
繁體中文
English
日文
說明(常見問題)
南開科技大學
圖書館首頁
編目中圖書申請
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Modelling and experimental study of ...
~
Carleton University (Canada).
Modelling and experimental study of automotive air-conditioning systems with consideration of two-component two-phase flow.
紀錄類型:
書目-電子資源 : 單行本
正題名/作者:
Modelling and experimental study of automotive air-conditioning systems with consideration of two-component two-phase flow./
作者:
Wang, Shujun.
面頁冊數:
213 p.
附註:
Source: Dissertation Abstracts International, Volume: 68-11, Section: B, page: 7631.
Contained By:
Dissertation Abstracts International68-11B.
標題:
Engineering, Automotive. -
電子資源:
Download PDF (下載PDF全文)
ISBN:
9780494335154
Modelling and experimental study of automotive air-conditioning systems with consideration of two-component two-phase flow.
Wang, Shujun.
Modelling and experimental study of automotive air-conditioning systems with consideration of two-component two-phase flow.
- 213 p.
Source: Dissertation Abstracts International, Volume: 68-11, Section: B, page: 7631.
Thesis (Ph.D.)--Carleton University (Canada), 2007.
The purpose of this thesis work was to investigate the performance of an automotive air-conditioning system experimentally and theoretically, with consideration of two-phase flow and oil concentration. An automotive air-conditioning test system with real size automotive air-conditioning components has been established to operate as a Clutch Cycling Orifice Tube system, which can measure the vapour quality and oil concentration. A Stream Analysis Model for an accumulator of automotive air-conditioning systems has been developed, and validated by the experimental results. A swash plate compressor of automotive air-conditioning has been investigated experimentally, and the effects of two-phase flow and oil concentration on its performance have been studied. The effects of refrigerant charge, inlet air temperature to evaporator, condenser surroundings temperature, and compressor speed on the performance of automotive A/C systems have been also investigated experimentally. A new automotive A/C system with an accumulator-capillary tube-suction line heat exchanger has been developed and investigated experimentally with comparison to a conventional system without an internal heat exchanger, and a system with a liquid line-suction line heat exchanger. The results show that the new system has better performance than the conventional system, such as higher cooling load and coefficient of performance, and better compressor working conditions.
ISBN: 9780494335154Subjects--Topical Terms:
1000006179
Engineering, Automotive.
Modelling and experimental study of automotive air-conditioning systems with consideration of two-component two-phase flow.
LDR
:02357nmm 2200253 4500
001
1000005069
005
20081017121309.5
008
081017s2007 ||||||||||||||||| ||eng d
020
$a
9780494335154
035
$a
(UMI)AAINR33515
035
$a
AAINR33515
040
$a
UMI
$c
UMI{me_controlnum}
100
1
$a
Wang, Shujun.
$3
1000006278
245
1 0
$a
Modelling and experimental study of automotive air-conditioning systems with consideration of two-component two-phase flow.
300
$a
213 p.
500
$a
Source: Dissertation Abstracts International, Volume: 68-11, Section: B, page: 7631.
502
$a
Thesis (Ph.D.)--Carleton University (Canada), 2007.
520
$a
The purpose of this thesis work was to investigate the performance of an automotive air-conditioning system experimentally and theoretically, with consideration of two-phase flow and oil concentration. An automotive air-conditioning test system with real size automotive air-conditioning components has been established to operate as a Clutch Cycling Orifice Tube system, which can measure the vapour quality and oil concentration. A Stream Analysis Model for an accumulator of automotive air-conditioning systems has been developed, and validated by the experimental results. A swash plate compressor of automotive air-conditioning has been investigated experimentally, and the effects of two-phase flow and oil concentration on its performance have been studied. The effects of refrigerant charge, inlet air temperature to evaporator, condenser surroundings temperature, and compressor speed on the performance of automotive A/C systems have been also investigated experimentally. A new automotive A/C system with an accumulator-capillary tube-suction line heat exchanger has been developed and investigated experimentally with comparison to a conventional system without an internal heat exchanger, and a system with a liquid line-suction line heat exchanger. The results show that the new system has better performance than the conventional system, such as higher cooling load and coefficient of performance, and better compressor working conditions.
590
$a
School code: 0040.
650
4
$a
Engineering, Automotive.
$3
1000006179
650
4
$a
Engineering, Mechanical.
$3
170925
690
$a
0540
690
$a
0548
710
2
$a
Carleton University (Canada).
$3
1000005475
773
0
$t
Dissertation Abstracts International
$g
68-11B.
790
$a
0040
791
$a
Ph.D.
792
$a
2007
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=NR33515
$z
Download PDF (下載PDF全文)
0 筆讀者評論
館藏地:
全部
線上資料庫
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約人數
備註欄
附件
OE0001044
線上資料庫
一般借閱
線上電子書
OE
一般(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
建立或儲存個人書籤
書目轉出
取書館別
處理中
...
變更密碼
登入